postervast.blogg.se

120v ac base motion sensor light bulb lamp
120v ac base motion sensor light bulb lamp









120v ac base motion sensor light bulb lamp
  1. 120V AC BASE MOTION SENSOR LIGHT BULB LAMP INSTALL
  2. 120V AC BASE MOTION SENSOR LIGHT BULB LAMP SERIES

³)The photocells red wire (its "line") you will wire to the black wire that comes from your light fixture.

120v ac base motion sensor light bulb lamp

²)When turned on the light switchs' outbound black becomes the a continuation of the "line" relative the photocell.so wire those 2 black wires together. Then your light switch should have another black out of it, a white neutral (think of the white as another ground wire that's taking the long path to ground back at the breaker panel where the white and your bare copper ground wires all become 1), and a ground wire that's typically a bare copper wire in and sometimes a green wire ¹) whenever possible I will always try to connect my grounds first, they are a sort of safety net if you screw up or if something is miswired elsewhere or a short occurs, because electricity ALWAYS takes the path of least resistance getting to that ground and thankfully copper wire has less resistance than human flesh.

120v ac base motion sensor light bulb lamp

The black going into your light switch is the "line" it's the 120v inbound line. Now if you're the type to make toast while taking a bath I'll understand why you ignored this most important rule.the rest of you.drill it in your head.no matter how small or fast the fix is Always turn the power off at the breaker. Remember a little taser uses just a a little 9volt battery but that's a discussion for another time on volts amps transformers and capacitation). ⁰)Turn the circuts power off at the breaker so there's no power to the circut you're going to work on.not just turn the switch off thinking it's then safe (half of that switch even when turned off carries 120 volts at 15-20amps. Remove lose jewelry and rings tie back longer hair etc.you really set don't want an arc welded wedding ring stuck on your finger and the switch box and still at 800☏ or more. Good practice for DIYers is wear rubber soled shoes or similar insulating shoes and even stand on an insulating mat of rubber or similar if you have it. Preferably our body isn't what connects that electricity to the ground. Hi there, Firstly, safety safety safety! Electricity is always trying to get back to the earth/ground, we're just caging it and controlling it to do work for us before allowing it to go home. It took some digging but I found them on-line from ZING EAR. When that gave the same results, I concluded that ONLY a two-wire controller would work. To make sure it was not a faulty photocell, I had to check with another, new one. When the three-wire photocells fail, they do so in the "ON" position. But this means that with a three-wire control, in any configuration, electricy is able to flow through the device to the load (the LED lamps).

120V AC BASE MOTION SENSOR LIGHT BULB LAMP SERIES

They appear to be designed with an internal electronic relay to allow the device to handle heavy electrical loads, whereas a two-wire photocell in series easily handles current for a couple of low amp LED lamps. I've tried all configurations, but I have to face the fact that the 3-wire photocells require a parallel circuit with a hot and a return. It wore out recently and the only replacements available were 3-wire. I installed a two-wire photocell controller about 20 years ago. It is impractical to try and run a return line. The posts are about 140 feet from each other and the wall switch is remote from both. So that post light is in series with the other, like old fashinoned Christmas tree lights used to be.

120V AC BASE MOTION SENSOR LIGHT BULB LAMP INSTALL

No ground, no return just two white wires to one where I wanted to install a photocell controller.











120v ac base motion sensor light bulb lamp